Display Component Requirements

Use the Component Requirements Inquiry (MRI) program to display components of a manufacturing order. See Road Map for work flow.

Note
If you accessed this program from another program, skip step 1.

  1. Enter a manufacturing order number or click the Lookup icon and use the standard lookup options to select the order from a list.

The program displays these header fields:

Field Name

Displays

Mfg order number

The manufacturing order number that you entered or selected followed by its status:

Complete

The order quantity has been received into on-hand inventory

Closed by user

User clicked Close order in the Manufacturing Maintenance (MIM) program

Closed by rcv

Received less than quantity ordered and clicked Close order? in the Receiver Maintenance (IRC) program

In picking

Some components have been picked

Open

No components have been picked

Partial

Some have been received into on-hand inventory

Printed

Shop paper has been printed or queued for printing

Pending close

Order has not been received to stock with the Receiving and Inspection (IRI) program

Parent item no

The parent item number ordered

Description

The description of the parent item

ECL

The engineering change level for this manufacturing order

RRL

The routing revision level for this manufacturing order

Demand order type

The order type of the demand order

Demand order no

The first demand order associated with this manufacturing order

Qty ordered

The quantity to be manufactured for this order

Qty scrapped

The quantity of this parent that has been scrapped

Qty received

The quantity that has been received into inventory

Qty rejected

The quantity of this item rejected during inspection

Qty stocked

The quantity received into inventory in the stocking unit of measure; this quantity can differ from the Qty received if some are awaiting inspection

Released

The date the manufacturing order was created

Due

The date this manufacturing order is due

Start

The manufacturing start date

Picked

The date components were picked

Completed

The date this order was completed

Followed by details for each component on the manufacturing order:

Field Name

Displays

Comp item no

The component item number

Description

The component item description

Qty open

The quantity of the component required but not yet obligated: Quantity required - Quantity obligated

0 if obligated, picked, or completed

Qty on order

The quantity ordered on requisitions, purchase orders, manufacture orders, and incoming transfers

Qty on hand

The quantity in on-hand inventory

Qty in flr stk

The quantity in floor stock

Qty available

Quantity on hand - Obligated or Quantity on hand - Committed depending on your setting for the Calc available using obligated/committed program option

Inv obligation

The quantity obligated for all orders, not just this order

Qty committed

The quantity committed for all orders, not just this order

Comp due

Component due date (start date of the order plus any bill of material lead time offset)

Op seq

The routing operation sequence associated with the component

Part des

The identifier your company uses to distinguish multiple occurrences of a component in the same bill of material

Stk UOM

The stocking unit of measure for the selected component

Prod cl

The product class assigned to this component

Qty required

The quantity required to build the quantity of the parent item for this order

Qty excess picked

The quantity over-picked: Qty required - (Qty picked + Qty Obligated)

Qty obligated

The quantity of this component that has been obligated

Qty in picking

The quantity obligated, but not yet picked

Qty scrapped

The quantity scrapped during manufacturing

Qty rejected

The quantity rejected during inspection

Qty closed

The quantity closed

Qty picked

The quantity picked for the selected component

  1. Choose the appropriate options:

To

Do This

Review your options for this program

Click Prog opts. See step 3.

Print the component listing

Click Print. See Print an Inquiry.

Display commitments and orders for the parent item

Click Parent. See Display Commitments and Orders. Click OK to return to this program.

Display commitments and orders for the selected component

Click Component. See Display Commitments and Orders. Click OK to return to this program.

Specify a different manufacturing order

Click OK. See step 1.

Exit the program

Click Exit.

  1. Click Prog opts to review your options. To change them:

    1. Click the Runtime tab to set runtime options. See Set Options for Reports and Inquiries for more information.

    2. Click the Program tab to set this program-specific option:

Field Name

Type / Max Length

Action / Description

Calc available using obligated/committed

Required
1 alphanumeric

Select O to calculate available as Quantity on hand - Obligated or select C to calculate available as Quantity on hand -  Committed.

    1. Click Save to save these options for future use.

    2. Click Refresh to display current options.

    3. Click OK to apply these options or click Cancel to exit without applying them.