Add a Component to a Bill of Material
When you click Component in the Bill of Material Maintenance (MPS) program, you can add or change, copy, or delete a component, and merge components from another bill of material. See Background and Road Map for more information.
If components exist for the selected parent and ECL, they are listed:
Field Name |
Displays |
||||||||
Comp item no |
The component item number |
||||||||
Description |
The description of the component |
||||||||
Stk UOM |
The stocking unit of measure |
||||||||
Part des |
The part designator or identifier your company uses to distinguish multiple occurrences of a component in the same bill of material |
||||||||
Qty per assy |
The quantity required to build one parent |
||||||||
Effective |
The date this component starts to be used in building this parent/ECL |
||||||||
Expiration |
The date after which the component will not be used in building this parent/ECL |
||||||||
Ref cd |
The reference code |
||||||||
M/B/K |
The
make/buy/kit code: |
||||||||
LLC |
The low level code |
||||||||
FS cd |
The floor stock code |
||||||||
Sub |
Substitution code:
|
||||||||
Picking whse |
The warehouse location from which the component is backflushed |
||||||||
Picking bin |
The bin location from which the component is backflushed |
||||||||
Op seq |
The operation sequence at which the component is picked |
Click Add if components exist. The parent item number, description, current ECL, ECL you are maintaining, and stocking unit of measure are displayed for information.
Enter or change data in these fields:
Field Name |
Type / Max Length |
Action / Description |
Comp item no |
Required |
Enter the item number of a component or click the Lookup icon and use the standard lookup options to select the component from a list. Its description and item status are displayed to the right of the item number. Note * displayed in the color associated with the bold attribute |
Part designator |
Optional |
Enter the identifier your company uses if this component is to be listed on this bill of material more than once. You may call this designator a balloon number, bubble number, file number, material tag, or reference number. |
Qty per assy |
Required |
Enter the quantity
of this component (in its stocking unit of measure) required to
build one parent. For example, if the parent is a table and the
component is a leg, you would enter 4. You can enter .00000 for
a component whose usage is insignificant. For by-product items, enter a negative quantity per. For example,
if you pick a large piece of sheet metal and cut off a small section,
enter a negative quantity per under a different component number
to return the remaining sheet to stock. |
Reference code |
Optional |
Enter a reference
that your company uses. For example, you can use this field to
associate this component with its balloon or bubble number on
the engineering drawing. |
Flr stk cd |
Required |
Accept the displayed code, select 0 to pick this component from on-hand inventory, or select 1 to backflush it from floor stock. The default code comes from the Flr stk cd field in the item's record in the Branch Item Maintenance (IMB) program. Items with control numbers cannot be assigned a floor stock code of 1. |
LT offset |
Optional |
Enter the number of shop days after the manufacturing order start date (due date minus lead time for the item) that this component is required. For example, an offset of 0 means the component is required at the manufacturing order start date; an offset of 3 indicates that the component is not required until 3 shop days after the manufacturing order start date. The offset cannot be greater than the lead time of the parent. Planning uses the lead-time offset to calculate delivery and due dates. |
Setup matl loss |
Optional |
Enter the quantity of material that you typically lose during the setup of an operation. For example, if the first two items produced after calibrating the machine do not meet quality standards, you would enter 2. Setup material loss is included in a cost rollup of a parent item: (Setup matl loss x Standard unit cost) / Standard lot size. Note |
Scrap % |
Optional |
Enter the percent of this component that you normally scrap during manufacturing. The system increases the quantity required by this scrap factor: (Quantity ordered x Qty per assy) + (Quantity ordered x Qty per assy x Scrap % x 0.01) rounded up to the nearest integer. If your scrap factor is 5%, enter 5.00. The Manufacturing Order Maintenance (MIM) and Shop Paper Print
(MSP) programs add the results of this calculation to the quantity
required. |
Effective date |
Required |
Select the date when this component will be used for manufacturing orders, enter a date shortcut, or leave blank to use 01/01/1900. |
Expiration date |
Required |
Select the date through which this component will be used for manufacturing orders, enter a date shortcut, or leave blank to use 12/31/9999. |
Date revised |
Optional |
Accept the displayed login date, select another date, or enter a date shortcut when you revised this BOM. |
Component type |
Optional |
Enter the component type your company uses. This field is not used by the system, but you can use it in the custom reports. |
Operation seq no |
Conditional |
If you want to backflush picking, enter the operation sequence number when you want the system to pick this component. For example, if this component is not required until the third operation, enter that sequence number. If you selected the Backflush comps not attached to oper? option for your manufacturing branch in the System Options Maintenance (XM) program (Manufacturing Options), leave blank to pick this component when you enter pieces completed for the first operation. You can enter pieces completed in either the WIP Movement (WIPM) or Labor Entry (LLE) programs or import them with the Labor Import (LEI) program. |
Comp reference |
Optional |
Enter the reference your company uses. Note |
Picking warehouse |
Optional |
Select the warehouse location from which the component is backflushed. |
Picking bin location |
Optional |
Select the bin location from which the component is backflushed. |
Replacement item? |
Optional |
Select if you replace this component under warranty or leave blank if you do not. |
Critical item? |
Optional |
Select if this component is critical to this BOM or leave blank if it is not. If you select, the Manufacturing Order Picking Selection (MSS) program displays a C in the Pck? column when you have a shortage of this item. |
Subs prohibited? |
Optional |
Select to prohibit the use of a substitute item for this component or leave blank to allow substitution. |
Pick per receipt? |
Optional |
Select if you want backflushed components to be rounded based on the current receipt quantity or the total received for order. See Overview: Component Backflushing. |
Choose the appropriate options:
To |
Do This |
Accept the data |
Click OK. |
Change a field |
Move to the field, make changes and click Apply. |
Exit without making changes. |
Click Cancel. |
Enter notes for this component |
Click Notes. See Enter Notes. |
Enter data in custom fields your company uses |
Click User. See Enter Data in User Fields or Shadow File Fields. Note |
Enter a substitute for this component |
Click Subs.
See Enter a Substitute Component. |
Display the bill of material for this component |
Click Comp bill. See Change a Bill of Material. This button displays only if this component is the parent of a subassembly. |
Display approval status for bills of material |
Click Approvals.
See Display Bill of Material Approval
Status. |
Display the changes made to this component |
Click Audit. See Display an Audit Trail. Click Exit after you view the audit trail to return to this program. Note |
Display the item's inventory status |
Click Inv status. See Inventory Status Inquiry. Click Exit to return to this program. |
Swap this component item with a substitute item |
Click Swap item. See Background for more information. |
Choose the appropriate options when you click OK or Cancel:
To |
Do This |
Add another component |
Click Add. |
Delete the selected component |
Click Delete. See Delete. |
Copy a component from another bill of material to this BOM |
Click Copy. See Copy a Component to a Bill of Material. |
Display the selected component |
Click Select. |
Display other parent items that use the selected component |
Click BOM where-used. See Display Component Usage in Standard Bills of Material. Click OK to return to this program. |
Merge components from another bill of material into this BOM |
Click Bill merge. See Merge Components from Another Bill of Material. |
Exit the component list |
Click OK. See Enter a Bill of Material. Click Exit to return to the menu. |