Add a Component to a Bill of Material

When you click Component in the Bill of Material Maintenance (MPS) program, you can add or change, copy, or delete a component, and merge components from another bill of material. See Background and Road Map for more information.

If components exist for the selected parent and ECL, they are listed:

Field Name

Displays

Comp item no

The component item number

Description

The description of the component

Stk UOM

The stocking unit of measure

Part des

The part designator or identifier your company uses to distinguish multiple occurrences of a component in the same bill of material

Qty per assy

The quantity required to build one parent

Effective

The date this component starts to be used in building this parent/ECL

Expiration

The date after which the component will not be used in building this parent/ECL

Ref cd

The reference code

M/B/K

The make/buy/kit code:
M: Make the item
B: Buy the item
K: Sell a configured product as an unassembled set of components

LLC

The low level code

FS cd

The floor stock code

Sub

Substitution code:

I

Substitute component exists for the item master

C

Substitute component exists on the bill of material component

B

Substitute component exists for both the item master and the bill of material component

N

No substitutes allowed for this component—the Subs prohibited? check box is selected

Picking whse

The warehouse location from which the component is backflushed

Picking bin

The bin location from which the component is backflushed

Op seq

The operation sequence at which the component is picked

 

  1. Click Add if components exist. The parent item number, description, current ECL, ECL you are maintaining, and stocking unit of measure are displayed for information.

  2. Enter or change data in these fields:

Field Name

Type / Max Length

Action / Description

Comp item no

Required
24 alphanumeric

Enter the item number of a component or click the Lookup icon and use the standard lookup options to select the component from a list. Its description and item status are displayed to the right of the item number.

Note
The component's status is highlighted* if it is not active (i.e., Item status in IM) is not 0.

* displayed in the color associated with the bold attribute

Part designator

Optional
8 alphanumeric 

Enter the identifier your company uses if this component is to be listed on this bill of material more than once. You may call this designator a balloon number, bubble number, file number, material tag, or reference number.

Qty per assy

Required
12 numeric in the format 9999999.99999

Enter the quantity of this component (in its stocking unit of measure) required to build one parent. For example, if the parent is a table and the component is a leg, you would enter 4. You can enter .00000 for a component whose usage is insignificant.

When a manufacturing order is created, the any fractional requirement is rounded to the next integer. For example, if you use paint and the stocking unit of measure is gallon, a usage of .01000 and a manufacturing order quantity of 10 will result in a paint requirement of 1 gallon. Consider using a smaller unit of measure (e.g., ounces in this example) for better reflection of the actual requirement.

For by-product items, enter a negative quantity per. For example, if you pick a large piece of sheet metal and cut off a small section, enter a negative quantity per under a different component number to return the remaining sheet to stock.

A negative entry is not allowed on items with control numbers.

Reference code

Optional
4 alphanumeric

Enter a reference that your company uses. For example, you can use this field to associate this component with its balloon or bubble number on the engineering drawing.

The Multi-Level BOM Listing (MPL) program can print components in sequence by this reference code rather than in item number order.

Flr stk cd

Required
1 alphanumeric

Accept the displayed code, select 0 to pick this component from on-hand inventory, or select 1 to backflush it from floor stock.

The default code comes from the Flr stk cd field in the item's record in the Branch Item Maintenance (IMB) program.

Items with control numbers cannot be assigned a floor stock code of 1.

LT offset

Optional
5 numeric in the format 999.99

Enter the number of shop days after the manufacturing order start date (due date minus lead time for the item) that this component is required.

For example, an offset of 0 means the component is required at the manufacturing order start date; an offset of 3 indicates that the component is not required until 3 shop days after the manufacturing order start date. The offset cannot be greater than the lead time of the parent. Planning uses the lead-time offset to calculate delivery and due dates.

Setup matl loss

Optional
9 numeric in the format 9999.99999

Enter the quantity of material that you typically lose during the setup of an operation.

For example, if the first two items produced after calibrating the machine do not meet quality standards, you would enter 2.

Setup material loss is included in a cost rollup of a parent item: (Setup matl loss x Standard unit cost) / Standard lot size.

Note
If you do not have a routing established for the item, the cost rollup assumes a standard lot size of one.

Scrap %

Optional
5 numeric in the format 999.99

Enter the percent of this component that you normally scrap during manufacturing. The system increases the quantity required by this scrap factor: (Quantity ordered x Qty per assy) + (Quantity ordered x Qty per assy x Scrap % x 0.01) rounded up to the nearest integer. If your scrap factor is 5%, enter 5.00.

The Manufacturing Order Maintenance (MIM) and Shop Paper Print (MSP) programs add the results of this calculation to the quantity required.

Scrap is calculated for backflushed components based on the current scrap percentage when an operation sequence is completed.

Effective date

Required
10 date

Select the date when this component will be used for manufacturing orders, enter a date shortcut, or leave blank to use 01/01/1900.

Expiration date

Required
10 date

Select the date through which this component will be used for manufacturing orders, enter a date shortcut, or leave blank to use 12/31/9999.

Date revised

Optional
10 date

Accept the displayed login date, select another date, or enter a date shortcut when you revised this BOM.

Component type

Optional
3 alphanumeric

Enter the component type your company uses. This field is not used by the system, but you can use it in the custom reports.

Operation seq no

Conditional
4 alphanumeric

If you want to backflush picking, enter the operation sequence number when you want the system to pick this component. For example, if this component is not required until the third operation, enter that sequence number.

If you selected the Backflush comps not attached to oper? option for your manufacturing branch in the System Options Maintenance (XM) program (Manufacturing Options), leave blank to pick this component when you enter pieces completed for the first operation.

You can enter pieces completed in either the WIP Movement (WIPM) or Labor Entry (LLE) programs or import them with the Labor Import (LEI) program.

Comp reference

Optional
30 alphanumeric

Enter the reference your company uses.

Note
This field may have a different label based on the Component reference user label option for your manufacturing branch in System Options Maintenance (XM) program (Manufacturing Options).

Picking warehouse

Optional
2 alphnumeric

Select the warehouse location from which the component is backflushed.

Picking bin location

Optional
8 alphnumeric

Select the bin location from which the component is backflushed.

Replacement item?

Optional

Select if you replace this component under warranty or leave blank if you do not.

Critical item?

Optional

Select if this component is critical to this BOM or leave blank if it is not.

If you select, the Manufacturing Order Picking Selection (MSS) program displays a C in the Pck? column when you have a shortage of this item.

Subs prohibited?

Optional

Select to prohibit the use of a substitute item for this component or leave blank to allow substitution.

Pick per receipt?

Optional

Select if you want backflushed components to be rounded based on the current receipt quantity or the total received for order. See Overview: Component Backflushing.

  1. Choose the appropriate options:

To

Do This

Accept the data

Click OK.

If you added a component, the program prompts for another component. See step 2.

If you changed an existing component, the program returns to the ECL list.

Change a field

Move to the field, make changes and click Apply.

Exit without making changes.

Click Cancel.

Enter notes for this component

Click Notes. See Enter Notes.

Enter data in custom fields your company uses

Click User. See Enter Data in User Fields or Shadow File Fields.

Note
This button displays only if you have set up user fields for this program in the User Fields Maintenance (XMO) program.

Enter a substitute for this component

Click Subs. See Enter a Substitute Component.

A check mark on the button indicates that substitute components exist.

Display the bill of material for this component

Click Comp bill. See Change a Bill of Material.

This button displays only if this component is the parent of a subassembly.

Display approval status for bills of material

Click Approvals. See Display Bill of Material Approval Status.

This button displays only if approval is required.

Display the changes made to this component

Click Audit. See Display an Audit Trail. Click Exit after you view the audit trail to return to this program.

Note
This button displays only if you have activated M1 Product Structure in the Audit Trail Maintenance (XAT) program.

Display the item's inventory status

Click Inv status. See Inventory Status Inquiry. Click Exit to return to this program.

Swap this component item with a substitute item

Click Swap item. See Background for more information.

  1. Choose the appropriate options when you click OK or Cancel:

To

Do This

Add another component

Click Add.

Delete the selected component

Click Delete. See Delete.

Copy a component from another bill of material to this BOM

Click Copy. See Copy a Component to a Bill of Material.

Display the selected component

Click Select.

Display other parent items that use the selected component

Click BOM where-used. See Display Component Usage in Standard Bills of Material. Click OK to return to this program.

Merge components from another bill of material into this BOM

Click Bill merge. See Merge Components from Another Bill of Material.

Exit the component list

Click OK. See Enter a Bill of Material. Click Exit to return to the menu.